WVL - Troubleshooting Chart

Problem Causes Solution
WVL Not Watering Dead batteries.
WVL not addressed.
Improper solenoid or solenoid disconnected.
WVL is out of communication range.
Use the manual test function and replace batteries.
Verify WVL address (start from controller)
Use manual test function, check solenoid wiring including polarity (red and black)
Improve radio communications
Multiple Stations activate Possible duplicate addresses in WVLs. Stop all irrigation, then start one of the stations. If multiple stations start, change the address in one of the WVLs.
Controller Beeping No response from WVL.
Low battery warning from WVL.
Use WVL app to read which condition is being reported
Replace batteries and/or improve communications, as indicated
Controller Err Message No response from WVL.
Low battery warning from WVL.
Possible failure on another output module.
Use WVL app to read which condition is being reported
Replace batteries, improve communications, as indicated
Troubleshoot other output modules
 
Station turns on for 1 second, then turns off WVL is wired to AC solenoid (not compatible). Replace the solenoid with the required DC solenoid (Hunter model 458200). Red wires to red, black wires to black.

 