Residential & Commercial Irrigation
Residential & Commercial Irrigation
The dipswitch settings must match for the Transmitter and Receiver to communicate properly. The default setting is with all dipswitches set to the OFF position. The Transmitter dipswitches are pushed toward the battery contact springs. The Receiver …
The WFS is typically installed near the point of connection, in an appropriately-sized FCT tee. The WFS transmitter can connect to a host controller up to 500 ft/150 m away. WFS sensors operate with an impeller positioned in the flow through the pipes. As …
The WFS sensor is designed to install within an FCT tee fitting. See chart below for tee sizes and corresponding pipe diameters. HFS FCT Tee Fitting Models (All tees are glue/slip type fittings) Model Material Diameter (US) Diameter (mm) FCT 100 Schedule …
Legend: Hunter Wireless Flow Sensor and transmitter (WFS) Irrigation valve box per plan heat stamp lid with “FS” in Letters Finished grade in turf Adjacent turf (per plan) Adjacent mulch (per plan) Finished grade in planter bed Brick supports (4) Filter …
After applying power to either the sensor/transmitter or receiver, wait a minimum of 10 seconds for the power up sequence to complete. During this time there will be one or more LED blinks before the unit is ready for operation. Low Battery Indication …
When flow is occurring the sensor/transmitter will transmit sensor information at a maximum rate (depending on flow) of once every 5 seconds. The receiver LED will flash green at the same rate to indicate that flow is occurring. Proper irrigation system …
Working with WFS Hunter flow-capable controllers are designed to measure and record actual flow, shut off irrigation when a high flow condition occurs, and identify which stations caused the condition. The controller’s learn mode samples each station …
Flow sensors can potentially be damaged by winterization blow-out techniques, and should be removed prior to injecting compressed air into the pipes. WFS sensors are installed in FCT tee fittings. The flow sensor itself includes an impeller, which rotates …
Problem Cause Solution WFS not reading. Water shut off. Verify that no isolation valves are closed, and that the water source is on. Controller not configured. Check controller flow sensor setup. Enter sensor size (and location for sensor decoders) and …
Operating Specifications Temperature Pressures Humidity 0 to 140ºF/60ºC up to 200 psi/13.7 bar up to 100% Flow Range Flow-Sync Sensor Diameter Operating Range (Gpm) Minimum* Suggested Maximum** 1" 2 17 1½" 5 35 2" 10 55 3" 28 120 4" 34 195 * Minimum …
The FCT tee fitting comes with a plug that allows for installation of the FCT into the irrigation system prior to installing the sensor. This allows the FCT tee to be installed separately from the sensor and prevents damage during installation of the …
This section will give you a brief overview of some of the components of the WFS. Sensor Impeller : Rotates when flow is occurring O-rings : Provides sealing of sensor in sensor body Wire : Black wire connects to the sensor transmitter Transmitter …
ACC Controller I-Core Controller … WFS - ACC and I-Core Installation …
The PebbleCreek Villas 43B community is a homeowners’ association (HOA) situated on 3.5 acres (1.4 hectares) of land within the beautiful PebbleCreek Golf Resort in Goodyear, Arizona. Originally established in 2014, the HOA is dedicated to promoting …