Residential & Commercial Irrigation
Residential & Commercial Irrigation
The PGP ® is Hunter’s original product—the item that put the company on the map in 1981. Its exceptional design and impressive performance placed the rotor a cut above back then, and continuous improvements and enhancements have allowed it to remain the …
The easiest way to make adjustments on your Hunter rotor is to use a Hunter adjustment wrench . This tool can be purchased from your local distributor. There are two adjustments that can be made on your rotor, the arc and the radius . The arc adjustment …
Receive Hunter quality and Hunter performance with the right substitute for your non-Hunter sprinklers … Residential Rotors - Replacement Guide: PGP Ultra / I-20 …
Hunter Industries was built around the innovation of the PGP rotor, the industry's most reliable sprinkler. This video is an overview of Hunter residential and light commercial rotor. Learn the difference between Hunter ¾" inlet rotors and their advanced …
With a rotor tool, it's easy to adjust the left stop, but ever wonder how to adjust the right stop after install? Hunter Technical Support will show you two ways to adjust your Rotor Right Stop. This technique works for all rotors inculding Hunter's …
Adjusting the arc and radius of a rotor is an easy task. Most residential rotors are adjusted the same way. There are two adjustments that can be made on rotors, arc and radius. Arc: The degrees of coverage of a sprinkler from one side of pattern to the …
One of the most common reasons for a sprinkler to start leaking between the pop-up riser assembly and the body cap while it is in operation is because the riser seal is worn or there is debris between the seal and the riser … Replacing a Hunter Rotor …
Installing a nozzle on a rotor is relatively easy. The procedure is the same for the PGJ, SRM, PGP-ADJ, PGP Ultra and I-20 rotors. This video will teach you how to intall a nozzle for any Hunter rotors. … Installing a Nozzle on a Hunter …
The most common reason for a sprinkler to stop rotating is the accumulation of debris in the filter. This video will teach you how to clean the filter on your rotors. … Cleaning a Filter on a Hunter …
Situated in the heart of the River Sile Natural Park in the Venetian countryside, the H-FARM compound is home to the largest innovation hub in Europe. The one-of-a-kind campus is among the largest single-parcel agricultural estates in Italy. Amenities …
Precipitation rate is the speed at which water is being applied to a specific area. If you have excessively wet or dry areas, you can change the nozzle in the sprinkler to increase or decrease the precipitation rate. For dry areas, install a larger …
The trajectory and spray height of the water stream leaving a sprinkler nozzle is important information when designing and installing irrigation systems. A = Degrees of trajectory B = Max Height of …
It's a combination drain hole and flush hole . It's a drain hole because we need to drain the water from below the nozzle turret so it doesn't push up on the nozzle turret in freezing climates. It’s a flush hole because when the head retracts, water and …
Residential Rotors - Rotor Nozzle Installation Procedure …
Using the PRB, the regulator in the body will take incoming pressures of 55-100 PSI and reduce them down to 45 PSI. This provides the optimum nozzle pressure to deliver the correct size droplets to the landscape for maximum water efficiency. Please …
Yes, if you know the model of the existing manufacturer's sprinkler, you can use our Replacement Charts to find the appropriate Hunter pop-up or rotor that will have a similar flow and distance range. Hunter has rotors and sprinklers to fit all …
If the right side of the arc is not properly aligned, the results may be a wet walkway or a dry turf area. The right side arc can easily be realigned. NOTE: Prior to making the right side adjustment, make sure the top turret is reset. Rotate the turret …
Rotary sprinklers require a certain amount of pressure and flow to operate properly. If the rotor does not receive the pressure it needs to pop up a leaky head will result. Here are some things to look for when a rotor doesn't pop up properly: Problem: …
Production of the G-Type rotor was discontinued 14 years ago, though many are still in use today. If a G-Type rotor needs to be replaced, the PGP-ADJ or PGP-Ultra is the current equivalent replacement. … Residential Rotors - Equivalent …
The easiest of the rotor pressure gauges to use, the Rotor Pitot Gauge (P/N 280100), has a tube placed directly in front of the primary nozzle stream for an accurate working pressure (dynamic) reading. This gauge will work on all Hunter rotor sprinklers …
The HUNTER ADJUSTMENT WRENCH consists of a 3/32 Allen key, two convenient finger loops for gripping, and an opposite side arc adjustment key for all your Hunter rotor adjustments. The Hunter wrench can be purchased from your local distributor. You can …
Before installing rotatory sprinklers (rotors), ensure you have a good irrigation design plan and enough pressure for the rotors with good head-to-head coverage. If you are unsure, please get in touch with a professional . We have supplied details for …
Learn why Hunter rotors are trusted by irrigation professionals worldwide. Learn more about the features of the flagship PGP-ADJ, PGP Ultra, and I-20 and which one has the right features for your irrigation project. … Hunter Rotors: The Most Efficient Way …
Do you like heroes who battle villains and save the day? If so, this Smart Irrigation video by Hunter Industries is for you! We highlight the real heroes - the professional irrigation contractors - who fight the villains of efficient irrigation. By using …