Residential & Commercial Irrigation
Residential & Commercial Irrigation
The Pro-C controller is equipped with a delay between stations function. This feature allows the user to select a time delay between the end of one station run time and the start of another station's run time. The delay can be as short as a one second or …
These tables are designed for quick reference and are set up to provide maximum wire runs, given the information at the bottom of the table. Maximum one-way distance in feet between controller and valve heavy-duty solenoid: 24 VAC, 350 mA inrush current, …
Irrigation systems utilize a 24VAC electronic signal to initialize a valve's solenoid. Even though the system is low voltage, it is still always recommended a trained professional perform these tests. … Using the AC voltage reading on your voltmeter, …
In an effort to get the irrigation industry focused on water conservation and Smart Irrigation Month, Hunter Industries is offering a chance to win a free trip to the 2013 Irrigation Association show in Austin, TX. Details for the promotion can be found …
As one of the premier 55+ active adult community in Florida, On Top of the World Communities is an award-winning, family owned building and land development company founded in 1947. Today, On Top of the World remains the oldest, privately owned land …
Station # ERR Message CAUSE - The Station # ERR (for example 1 ERR) is a diagnostic message that appears when your controller is detecting a fault on that corresponding irrigation zone. SOLUTION - To determine the cause of this message it is necessary to …
Pro-C - "NO AC" on Display The "NO AC" display is a diagnostic message telling you that the controller has stopped receiving AC power. The controller is running on the power supplied by the backup battery. Check the power source by plugging a lamp or …
Pro-C - No Display First, make sure there is power to the controller's outlet. Use a test lamp or any other 110VAC device to determine if there is voltage at the outlet. If there isn’t power there, or if you have a controller that is hard wired, check the …
Pro-C - Flashing Sprinkler Icon, No Zones Running If the controller display shows a station running, flashing sprinkler icon, or arrow pointing towards running, it sounds like the controller is doing its part. Maybe the water has been shut off to the zone …
Pro-C - Not Recognizing Correct Stations If your Pro-C controller is not recognizing all of your stations in the "Set Station Run Times" or "Run Times" dial position, you may need to reset the station modules. Note: The numbers represented in the "Program …
Outdoor mounted controllers: Leave the power on and the dial / switch in the "OFF" position. The heat from the transformer will keep the enclosure warm enough to keep condensation from forming inside the controller enclosure. The dial in the "OFF" …
SP ERR or ERR Message CAUSE - Noise entering the controller through the “SmartPort” wiring or it is wired incorrectly. SOLUTION - A few steps are necessary to determine cause of “Err” message. 1. Check SmartPort® Wiring If the “Err” message is displayed …
Pro-C - Station Repeats A common reason for a controller to repeat a cycle is too many programmed start times. Only one start time per active program is required, a second start time will cycle the program an additional time. NOTE: In the Start Times dial …
The Pro-C / PCC controller (with SOLAR SYNC position on dial) is programmed with the Solar Sync technology and, therefore, does not require the use of the Solar Sync module. The Solar Sync Sensor (SOLARSYNCSEN or WSSSEN) is wired directly to the “SEN” …
After Solar Sync has been installed and programmed, we recommend allowing the system to run for a few days at the initial setting. Because of the variety in site conditions (including sensor location, amount of direct sunlight available to the sensor, …