Hydrawise - Flow Meter Specifications

Specifications
HC Flow ModelHC-075-FLOW (¾")HC-100-FLOW (1")HC-150-FLOW (1½")HC-200-FLOW (2")
Inlet/outlet connection size ¾" NPT body, male thread  1" NPT body, male thread  1½" NPT body, male thread  2" NPT body, male thread 
Meter internal diameter 3/4"1"1.5"2"
Minimum flow (GPM) 0.22 0.3 0.88 1.98
Maximum recommended flow (GPM) 15 30 66 105
Maximum flow rate (GPM) 21 34 88 132
Dial reading (US gal) 1 pulse per 0.1 U.S. gal 1 pulse per 1 U.S. gal 1 pulse per 1 U.S. gal 1 pulse per 1 U.S. gal
Maximum working pressure (PSI) 230 230 230 230
Included Wire Length29" total wire length with first 8" having flex conduit.
Flex Conduit Thread SpecThreading measures ¼” BSP, which would also fit ¼” NPT for all models. The exact thread size of the stainless steel fitting is 1/4-28.  
Pressure Loss Chart