From the Home screen, the MANUAL soft key allows you to start stations/blocks, programs, and run a test program. A Manual Station or Program Start will pause any automatic watering until the Manual Program has been completed.
![](/sites/default/files/support_acc2_manual_starts_and_test.jpg)
Manual Stations
Select one or more stations to run manually with any amount of run time.
- Select the right soft key MANUAL.
- Select the right soft key MANUAL STATIONS.
- The default RUN TYPE is sequentially (one after another). Check the Simultaneous box to have the selected stations run simultaneously.
- Using the scroll wheel, select an EVENT. An event can be a single station, a P/MV or a block (group of stations).
- Using the scroll wheel, select a STATION NUMBER.
- Using the scroll wheel, select a RUN TIME.
- Select soft key START.
- Select soft key STOP to stop the operation.
![](/sites/default/files/aac2_manual_single.png)
Manual Program
Select a single PROGRAM to run manually that has preprogrammed information in the controller.
- Select the right soft key MANUAL.
- Select the right soft key MANUAL PROGRAM.
- Using the scroll wheel, select a PROGRAM NUMBER.
- Select soft key START.
- Select soft key STOP to stop the operation.
Test Program
The TEST PROGRAM will run all stations in the controller for the run time entered on the screen.
- Select the right soft key MANUAL.
- Select the right soft key TEST PROGRAM.
- Using the scroll wheel, select a RUN TIME.
- Using the scroll wheel, select a STATION number to start on. It is also possible to specify a station number, and run all remaining stations from that number to the highest numbered station.
- Select soft key START.
- Select soft key STOP to stop the operation.
Still need help? We're here.