Residential & Commercial Irrigation
Residential & Commercial Irrigation
The high velocities that are common during initial activation of an irrigation cycle could cause the Flow-Clik to sense a “high flow” situation (primarily due to air trapped within the system) and subsequently shut down the irrigation system at the …
The Flow-Clik monitors for a high flow condition, shutting down the system or individual zone when overflow occurs. Once the system has been shut off due to a high flow condition, the Flow-Clik turns the system back on automatically after a pre-selected …
The water may contain foreign objects such as sand, rocks, and other impurities, which can damage the rotor. To avoid these problems, you may need to install a filter. Troubleshooting non-rotation after installation: Check for plugged secondary nozzle and …
Now that the internal and external components are installed, turn on the system to verify functionality with the on-off-auto selector switch. Next, set the rotor arc. The ST-1600-HS-B Rotor has an arc range of 40° to 360°. It also has a ratcheting feature …
Hunter Copper Dripline (HDL-COP) provides triple protection for subsurface dripline applications with a slow-draining check valve, superior grit tolerance, and copper oxide-infused emitters for root growth prevention. Copper oxide has been proven to …
The Hunter ST-1600-KIT can now be purchased as a complete kit without ordering individual components. Reference the links below for a complete components list of each kit. ST 900 KIT ST 1600 KIT New Version Old Version Description STG-900-KIT STK-1 …
This support section will walk you through the installation and maintenance of the Hunter RZWS. … RZWS Support …
This guide outlines the application, design, and installation of Hunter’s inline drip products that provide designers, installers, and irrigation managers a new class of irrigation technology. It is written for professionals who have a solid understanding …
PLD-LOC - Insertion Instructions …
The Automatic Flush Valve (AFV) allows debris to be flushed out of any dripline system. It is good practice to install an AFV at the end of any single dripline or grid of dripline. Flush the zone prior to use. An AFV may be used for any dripline system …
Similar to a sprinkler head, the Eco-Indicator pops up to provide visual indication that a drip system is operating. The Eco-Indicator has a highly visible yellow stem that pops up when the system is running at a pressure of least 12 PSI (0.8 bar; 83 …
HDL-PC & HDL-R - Emitter Line Maximum Length …
This chart can help determine the spacing you need for your soil type. SOIL TYPE SAND LOAM CLAY Emitter Distribution - Illustration of how the water is distributed in different soils. Saturation Rate in/hr .75 - 1.25 .25 - .75 .15 - .25 mm/hr 19 - 32 6 …
Hunter POINT-SOURCE EMITTERS apply water slowly and directly at the base of the plant to ensure every drop is put to efficient use. They are available in three convenient styles, including self-piercing ¼" barb, 10-32 threaded fitting, and ½" female pipe …
Emitter tool for punching a pilot hole, inserting, and removing an emitter. … Emitter tool for punching pilot holes and pellets, inserting and removing an emitter, and cutting tubing. … Pocket Punch … HEMT - Hunter Emitter Multi-Tool … Emitter …
The Flow-Sync Sensor is designed to be installed within an FCT tee fitting, sized for the pipe in which it will be installed. Optional slip-BSP adapters are available separately for sizes up to 75 mm for international applications. Install the FCT tee …
All in-vault installations require the ST-IBS-1600 Infill Barrier System to blend the ST System with the surrounding field. The Infill Barrier System also creates a snug fit between the rotor and the vault cover, allowing for smoother operation. For …
Before attaching synthetic, track, or concrete material to the vault, cover, and Infill Barrier System, trim the walls of the Infill Barrier System to create a flat upper surface if using non-infill type material. If an infill-type material is being used, …
The FCT tee fitting comes with a plug that allows for installation of the FCT into the irrigation system prior to installing the Sensor. This allows the FCT tee to be installed separately from the sensor and prevents damage to the sensor during …
Operating Specifications Temperature Pressures Humidity 0 to 140ºF/60ºC up to 200 psi/13.7 bar up to 100% Flow Range Flow-Sync Sensor Diameter Operating Range (Gpm) Minimum* Suggested Maximum** 1" 2 17 1½" 5 35 2" 10 55 3" 28 120 4" 34 195 * Minimum …
Remove the sensor jumper across the two SEN terminals in the controller. Attach the two yellow wires to the 24 VAC terminals. Attach the blue wire to one SEN terminal and the white wire to the other SEN or SEN COM terminal. NOTE: Additional setup steps …
The receiver has two LED lights that indicate the state of the system. SENSOR STATUS LED: RED : Sensor is wet (watering disabled) GREEN : Sensor is dry (watering enabled). YELLOW : Sensor is in addressing mode. SENSOR BYPASS LED: RED: Rain sensor is …
Find a Distributor PART NUMBER DESCRIPTION WM-CLIK-TR Wireless Mini-Clik Sensor transmitter only WR-CLIK-R Wireless Mini-Clik Sensor receiver only 10023600SP Wireless Mini-Clik Sensor cap with spindle assembly 10023900SP Wireless Mini-Clik Sensor quick …