CONTROLLER SETTINGS offers more advanced features that can be accessed using the steps below. Open the Node-BT App and choose a controller Name. Select Connect . Select the More hamburger icon. Select Controller Settings . Location, Controller Name, …
Odd or Even day watering schedules are available on all Hunter controllers. … This feature uses numbered day(s) of the month for watering instead of specific days of the week (odd days: 1st, 3rd, 5th, etc.; even days: 2nd, 4th, 6th, etc.) With the cursor …
The DASHBOARD screen provides an overview of the programming within the app. Node controller battery strength (%) - This allows user to determine when battery need to be changed. Controller is set for AUTO or OFF - AUTO means controller will run per …
MANUAL OPERATION will allow you to turn on the following without changing any of the automatic settings. Existing program (A, B or C) - This allows you to turn on a program that has set run times and stations automatically programmed. Single station - …
The dry out time could be as little as 4 hours depending on the weather conditions (temperature and humidity) and the rain threshold that is set. If the weather conditions remain cold and damp, your sensor could be active for months. Hunter Rain Sensors …
Manual operation allows you to run a manual cycle from 0:01 (one minute) to a maximum of 6:00 (six hours). With the app open, select the MANUAL HAND icon. Select a RUN TIME . Click START . Click STOP to stop the manual operation. … Manual operation …
If your Hunter SRC controller’s display reverts back to the current time after trying to manually activate stations, it has more than likely undergone a power surge or is experiencing a technical anomaly. Most likely this controller will need to be …
A controller with a partial or blank display usually has damage to an electronic component on the internal circuit board. Normally this type of damage cannot be repaired. If the controller was installed outside be sure that the door remains closed …
The "NO AC" or "Blank" display is a diagnostic message telling you that the controller has stopped receiving AC power. For the "NO AC" message, the controller is most likely running on the power supplied by the backup battery. Check the power source …
The Erase All feature will erase all of the controller's memory and set everything back to factory presets. Once you perform an Erase All , all programming will be erased, including the Easy Retrieve saved programming. Erase All is usually performed when …
STEP ONE STEP TWO 1. From the home screen start by pressing the "Options" button. 2. Continue pressing the "Options" button until "Edit FC Settings" displays. FC stand for "Field Controller" as IDS system's are often referred as in the Golf industry. …
Step 1. Check the controller programming Is there a watering Start Time programmed into the controller? Is the Watering Start Time programmed with correct time of day (i.e. AM or PM)? Is the Current Time set correctly (i.e. AM or PM)? Is today a Water …
The NO AC display is a diagnostic message telling you that the controller has stopped receiving AC power. The controller is running on the power supplied by the backup battery. Check the power source by plugging a lamp or radio into the wall outlet to …
Facepack Identification Stops all irrigation; enables and disables Rain Shutdown. Sets run times and order for stations and Blocks. Accesses multiple options and controller settings. Different sets of options appear, depending on mode controller is in …
In order to properly handle your requests for any Hunter products under warranty, we need to know the date of manufacture for the items in question. Below you will find basic information on how to locate and read the date code on a variety of Hunter Golf …
All program information and manual watering is conducted with the WVP and individual WVC controllers using radio signals. Under normal conditions, these operations can be conducted up to 100 feet from the controller. The Transmit/Receive button on the …
When using the side strip nozzles, there are several different configurations that can be done with any given design. For this reason, we do not publish a PRECIPITATION RATE for these models. We would recommend using the TOTAL AREA METHOD to calculate …
If the controller display shows a station running, flashing sprinkler icon ( ), or an arrow pointing towards running, it sounds like the controller is doing its part. Maybe the water has been shut off to the zone valves. Go to the zone valve and turn …
A valve with an external leak can be a simple adjustment or may require further inspection. Review our simple checklist below. Crack in the body - This would require a valve replacement. Loose bolts/screws on the bonnet - Tighten down, so they are snug. …
Here are some common reasons why a pop-up sprinkler may stay stuck up: Debris in the pop up body The riser is damaged The riser seal is worn To fix this: Unscrew the body cap Pull out the sprinkler assembly Examine the parts Clean out debris Replace …
Here are some tips for valve repair. … Valves - Servicing Jar-Top Valves …
Over time general usage can cause riser seals to wear out, similar to the wiper blades on a car, they require replacement. The signs of this are usually heads that have riser stems stuck up after the operation, or excessive leaking around the riser seal …
Hunter manufactures an MP Gauge , this gauge can be used on all Hunter spray heads. Simply screw the Hunter nozzle of your choice onto the MP Adapters top thread, then apply the MP Adapter's bottom thread to the spray head's riser stem. MP Gauge includes: …
When using Centralus Software, you have the ability to change your STATION , BLOCK , and/or DELAY RUN TIMES . There is a maximum run time of 12:00 hrs for all model A2C controllers. The minimum run time is 15 seconds for the decoder model and 1 …