Landscape Irrigation
Landscape Irrigation
The I-Core Controller was discontinued in 2024. The recommended replacements for the I-Core are the ICC2 , HCC , and ACC2 Controllers , which offer comparable flow monitoring and smart weather adjustment capabilities plus the added flexibility of internet …
More than a simple programmer, the ICD-HP Handheld Programmer is a field tool designed to help decoder system operators work as efficiently and effectively as possible. This industrial-grade outdoor instrument saves installation and diagnostic time, and …
The ICD-HP Handheld Programmer is an innovative setup, programming, and diagnostic tool for Hunter ICD and DUAL series decoder products. The ICD-HP may be flash updated to the latest version, with a free download from the product Resources page. Version …
Download the DUAL Owner’s Manual for detailed instructions on how to install and program the two-wire decoder system for the I-Core irrigation controller. … DUAL Owner's …
DUAL 48M DUAL-1 DUAL-2 DUAL-S ID WIRE … Dual - System Components …
The DUAL48M decoder output module is designed for use in all Hunter I-CORE series controllers and provides two-wire decoder outputs for the Hunter DUAL family of field decoders. Note: This module is not compatible with any other controller. The decoder …
Hunter Industries brings you DUAL, a two-wire decoder system to be used with the already popular I-Core controller at a breakthrough price point. Dual offers faster installation, lower installation costs, increased flexibility, easy troubleshooting and …
Learn how to add a Hunter Dual two-wire decoder system to any project with step-by-step instructions on how to splice the wires and make the waterproof connections. … DUAL Decoders: On-Site …
Video 5 of 8 to installation of the Hunter Dual decoder two-wire system with I-Core controller. Connecting decoders to valve solenoids. … Hunter Dual Two-Wire Installation: Connecting Decoders to Valve Solenoids 5 of …
Video 6 of 8 of installation of the Hunter Dual decoder two-wire system with I-Core controller. Connecting DUAL-S surge suppressors in line and at the end of the wire. … Hunter Dual Two-Wire Installation: Connecting DUAL-S Surge Suppressors 6 of …
Video 4 of 8 installation of the Hunter Dual decoder two-wire system with I-Core controller. This section will go over connecting 2-Wire paths. … Hunter Dual Two-Wire Installation: Dual Connecting Two-Wire Paths 4 of …
Video 2 of 8 installation of the Hunter Dual decoder two-wire system with I-Core controller. Grounding the Controller is a vital step in the two wire installation. … Hunter Dual Two-Wire Installation: Dual Grounding 2 of …
Video 3 of 4 installation of the Hunter Dual decoder two-wire system with I-Core controller. In this section we will instal the Dual 48M decoder output module. … Hunter Dual Two-Wire Installation: Installing the Dual 48M Decoder Output Module 3 of …
Introduction to installation of the Hunter Dual decoder two-wire system with I-Core controller. This video series will go over DUAL, a two-wire decoder system to be used with Hunter I-Core controller. DUAL two-wire technology can change the way you look …
Video 8 of 8 of installation of the Hunter Dual decoder two-wire system with I-Core controller. Programming with the ICD-HP handheld programmer. … Hunter Dual Two-Wire Installation: Programming with the ICD-HP Handheld Programmer 8 of …
Video 7 of 8 installation of the Hunter Dual decoder two-wire system with I-Core controller. Tee-Splicing the two-wire path. … Hunter Dual Two-Wire Installation: Tee-Splicing the Two-Wire Path 7 of …
Hunter re-introduces the Dual-1 and Dual-2 decoders in a slim-line design. Other enhancements include solid copper red-and-blue wire leads, for more positive connections to the two-wire path, and a slightly reduced standby current draw (2.8 -3 mA). There …
Wire and wire installation is a key factor in successful decoder installations. Substitution of recommended wire and wire splices is at the installer’s own risk and is a major cause of start-up service troubles. Hunter provides two types of wire for use …
This is strongly discouraged by Hunter for the following reasons: It is unlikely that the pre-existing wire meets the specifications for gauge, twist, and solid copper. Pre-existing wire will not be color-coded correctly for the decoder wires. …
Note: If decoder(s) have not been installed on the two-wire path(s), the decoder output module will display “Line Open”. … Connecting the Two-Wire …
Proper grounding of decoder systems is part of the installation that requires consideration. Properly grounded decoder systems perform very well even in high-lightning regions. Poor grounding often results in unnecessary equipment losses and irrigation …
The DUAL decoder module has features and diagnostics to help you troubleshoot installation issues and check the status of solenoid operation. Basically, two functions are available to the user in the Diagnostic mode: Read Current Function Allows for real …
NOTE: Do not loop the two-wire path back to the controller Two Two-Wire Paths Single Two-Wire Path DUAL-S SURGE SUPPRESSION Decoder Controller Single Two-Wire Path With T-Splices ID1 : up to 5000ft/ 1500 m from controller to each end of wire paths. …
Controller power must be OFF when installing decoders in the two-wire path. Note: Decoder wire runs and connections must be completely waterproof. Decoder wiring is more critical than "conventional" 24 VAC solenoid wiring. Follow instructions closely! …