SRC
- Unplug the controller's transformer.
- Press and hold down the
, and buttons. - Plug the controller's transformer back in.
- Release the
, and buttons. The display should now show 12:00am. All the memory has been cleared and the controller may now be reprogrammed.
SRC Plus
- Press and hold down the
, and buttons. - Press and release the RESET button in the lower wiring compartment.
- Release the
, and buttons. The display should now show 12:00am. All the memory has been cleared and the controller may now be reprogrammed.
EC
- Press and hold down the
, and buttons. - Press and release the RESET button in the lower wiring compartment.
- Release the
, and buttons. The display should now show 12:00am. All the memory has been cleared and the controller may now be reprogrammed.
X-Core
- Press and hold down the
, and buttons. - Press and release the RESET button on the right side of the controller.
- Wait 2 seconds and release the , and buttons. The display should now show 12:00am. All the memory has been cleared and the controller may now be reprogrammed.
Pro-C (newer models)(with Seasonal Adjust Dial Position)
- Press and hold the button.
- Press and release the RESET button on the back of the front panel.
- Wait until the display shows 12:00am.
- Release the .
Pro-C (older models)(with Manual All Station dial position)
- Turn the dial to the RUN position.
- Remove the 9V battery.
- Hold down the , and program buttons simultaneously.
- While holding down the three buttons, press and release the Reset button on the back of the front panel.
- Release all three buttons.
ICC
- Turn the dial to the RUN position.
- Remove the 9V battery.
- Hold down the , and program buttons simultaneously.
- While holding down the three buttons, press and release the Reset button on the back of the front panel.
- Release all three buttons.
SVC
- Remove the 9V battery from the controller and wait 1 minute.
- Press and hold the , and buttons.
- Replace the 9V battery.
- Release the , and buttons.
NODE
- From the Time and Day display, press and hold the , and keys.
- After two seconds the screen will go blank and 4 segments will appear. Release the keys.
- 12:00 will flash on the display, now the controller can be reprogrammed.
ACC
- Press and hold the Programs button, and at the same time press in the recessed Reset button with the tip of a ball point pen.
- Release the Reset button and continue holding the Programs button until the Reset Memory screen appears (then release the Programs button).
The display will show the following Reset options:
Programs: Erases Day schedules, start times, and run times.
Flow Totals: Clears the running flow total histories (they will restart with 0.0 for all entries), only.
Logs: Clears all Station alarm logs and Controller alarm logs.
Names: Clears all user programmed names, including Programs, Stations and SSG's.
All Data: Clears all of the above items, and controller returns to original out-of-the-box programming state.
Use the up and down arrows to highlight the desired type of Reset. Press the + button to select it.
A confirmation message will appear. If + is pressed again, the selection will be reset.
Note: None of the reset functions will erase the Easy Retrieve "backup", if one has been made.