CONTROLLER SETTINGS offers more advanced features that can be accessed using the steps below. Open the Node-BT App and choose a controller Name. Select Connect . Select the More hamburger icon. Select Controller Settings . Location, Controller Name, …
The DASHBOARD screen provides an overview of the programming within the app. Node controller battery strength (%) - This allows user to determine when battery need to be changed. Controller is set for AUTO or OFF - AUTO means controller will run per …
MANUAL OPERATION will allow you to turn on the following without changing any of the automatic settings. Existing program (A, B or C) - This allows you to turn on a program that has set run times and stations automatically programmed. Single station - …
Hunter's ET System has a wind option that utilizes an anemometer to read local wind conditions. In some cases site conditions may require the anemometer to be located away from the ET Sensor. If this is the case, using 18AWG wire the anemometer can be …
Manual operation allows you to run a manual cycle from 0:01 (one minute) to a maximum of 6:00 (six hours). With the app open, select the MANUAL HAND icon. Select a RUN TIME . Click START . Click STOP to stop the manual operation. … Manual operation …
The ACC controller can be reset, erasing some, or all programmed information. There are 5 different levels of reset command available. Once any of them is chosen, the information will be permanently erased. Turn the dial to the RUN Position. Press and …
The Pro-C is compatible with the Hunter Solar Sync. Solar Sync is a sensor system that will automatically adjust the Pro-C controller’s watering run times (based on changes in local climate condition) by using the Seasonal Adjust function. The Solar Sync …
NOTE: In the Start Times dial position, the numbers 1-4 do not represent stations. The numbers represent the program start times. Each program can start up to 4 times on the set days to water. One start time will activate all stations sequentially in that …
When using the side strip nozzles, there are several different configurations that can be done with any given design. For this reason, we do not publish a PRECIPITATION RATE for these models. We would recommend using the TOTAL AREA METHOD to calculate …
Native plant restoration projects and subsurface drip irrigation systems often require temporary overhead watering to support delicate plants. To simplify temporary irrigation, two preassembled stake kits are available for use with high-efficiency MP …
Here are some tips for valve repair. … Valves - Servicing Jar-Top Valves …
All Hunter Industries Anti-Siphon Valves should be installed above ground and at least 6 to 12 inches above the highest sprinkler to prevent back pressure or drainage. Installations at any height lower than this may result in unsafe backflow condition. …
Warning : Before installing spray bodies, always remember to ensure you have a good irrigation design plan and enough pressure for the sprays with good head to head coverage. If you are unsure please contact a professional. Hunter provides installation …
Warning : Before installing spray bodies, always remember to ensure you have a good irrigation design plan and enough pressure for the sprays with good head to head coverage. If you are unsure please contact a professional. Hunter provides installation …
FloGuard Technology supplements the robust, field-proven features and benefits of the Hunter Pro-Spray® family with an additional level of water savings. When the nozzle is removed from the head of a Pro-Spray model with FloGuard, a single 10' tall …
When using Centralus Software, you have the ability to change your STATION , BLOCK , and/or DELAY RUN TIMES . There is a maximum run time of 12:00 hrs for all model A2C controllers. The minimum run time is 15 seconds for the decoder model and 1 …
Metal controllers will include a hole plug assembly in a pre-drilled factory hole on top of the controller. Remove the nut on the inside of the controller to remove the plug. Route the cable through the pre-drilled hole and the antenna nut. Then tighten …
After setting up an ACC2 or ICC2 controller in your Centralus account, you may choose to release the controller (serial number) to another user. This will require the controller's deletion. When the NEW user adds the controller into the Centralus …
If a customer claims and purchases a subscription for an A2C-LTE device and no longer wants to have ownership of the device, there is the option to cancel the subscription. When a customer cancels a subscription, the plan status will change to CANCELING …
Before securing the controller to the wall, you must first remove the lower wiring compartment door. The door can easily be removed by following the simple steps below: Open the external door using the included key if outdoor version model. Indoor version …
A Hunter weather sensor or other micro-switch type weather sensors can be connected to the Pro-C. The purpose of this sensor is to stop automatic watering when weather conditions dictate. Connecting a Hunter “Clik” Weather Sensor with a P2C Controller …
Node Program Capablities The NODE uses standard Hunter controller programming with 3 programs (A, B, C) and 4 start times per program. … On standard Hunter controllers a dial is used to scroll between the programming functions, however, on the NODE the …
Push the button until the icon is displayed. All 4 digits will be displayed representing the year. Use the or buttons to change the year. Press the button to proceed to setting the month. All 4 digits will be displayed with the two digits on the …
The standard MP Rotators have a matched precipitation rate of approximately 0.4 in/hr. This means any standard MP Rotator at any arc or radius can be placed on the same zone. The MP800SR can be configured to work well in head-to-head coverage in either …