Residential & Commercial Irrigation
Residential & Commercial Irrigation
Facepack Identification Stops all irrigation; enables and disables Rain Shutdown. Sets run times and order for stations and Blocks. Accesses multiple options and controller settings. Different sets of options appear, depending on mode controller is in …
In order to properly handle your requests for any Hunter products under warranty, we need to know the date of manufacture for the items in question. Below you will find basic information on how to locate and read the date code on a variety of Hunter Golf …
Simply twist the solenoid on the valve counter clockwise 1/4 turn to 1/2 a turn. To shut off the valve, twist the solenoid clockwise until it is snug on the valve. … How do I manually open a zone control valve without using the …
The X-Core is compatible with the Hunter Solar Sync. Solar Sync is a sensor system that will automatically adjust the X-Core controller’s watering run times (based on changes in local climate condition) by using the Seasonal Adjust function. The Solar …
This feature permits the user to stop all programmed waterings for a designated period from 1 to 7 days. At the end of the programmed rain off period, the controller will resume normal automatic operation. … The days off remaining will decrease at …
After programming the X-Core, set the dial to the RUN position to enable automatic execution of all selected watering programs and start times. … X-Core - Automatic …
To stop a station from running when the system cycles automatically, simply remove all station Run Times for station that you do not to operate. Make sure Programs A, B, C and on some controllers Program D, have a run time set to "0:00" for station that …
If your controller shows irrigation running (Flashing Sprinkler Icon), and your sprinklers are not working, you may have a wiring problem at the valves or the irrigation water supply has been shut down. If you have a master valve on your system (check for …
There are a number of reasons why the sprinklers may not come on from the automatic program. Assuming the controller will run the zones from the controller manually, you most likely have a programming issue. Below are a few possible causes to the …
This feature allows you to quickly diagnose wiring problems with your controller. Instead of having to check each field wiring circuit for potential problems, you can use the Hunter Quick Check circuit test procedure. To initiate the Quick Check test …
The X-Core is compatible with the Hunter Wireless Solar Sync. Solar Sync is a sensor system that will automatically adjust the X-Core controller’s watering run times (based on changes in local climate condition) by using the Seasonal Adjust function. The …
For accurate Solar Sync measurements, the controller needs to be programmed for the average peak season ET for your region. Use the following table for choosing your region. You can use methods A, B or C to help you choose which region is best for your …
If a Solar Sync sensor has been installed on the X-Core controller then the seasonal adjust value used by the controller will be calculated from the weather data supplied by the Solar Sync sensor. If it is decided that the Solar Sync sensor will no longer …
The X-Core controller will not water manually or automatically with the dial in the system off position. Valves currently watering will be shut off after the dial is turned to the system off position. The display will flash OFF for two seconds then …
A controller can sometimes experience a “glitch” if it has received a power surge or other electrical anomalies. Your controller may not be damaged, however, it may require resetting. A successful reset will result in a 12:00 am on the display. Here is …
The X-Core allows the user a simplified method for running a test program. This feature will operate each station in numerical sequence, from the lowest to the highest. … After a 2 second pause, the test program will start. The display will show the …
If the controller display shows a station running, flashing sprinkler icon ( ), or an arrow pointing towards running, it sounds like the controller is doing its part. Maybe the water has been shut off to the zone valves. Go to the zone valve and turn …
Using the PRB, the regulator in the body will take incoming pressures of 55-100 PSI and reduce them down to 45 PSI. This provides the optimum nozzle pressure to deliver the correct size droplets to the landscape for maximum water efficiency. Please …
Yes, if you know the model of the existing manufacturer's sprinkler, you can use our Replacement Charts to find the appropriate Hunter pop-up or rotor that will have a similar flow and distance range. Hunter has rotors and sprinklers to fit all …
The stainless steel option on Hunter rotors offers mutliple benefits, here are a few: Vandal Resistance - Parks and other common ground areas that have heavy foot traffic can sometimes create vandal issues with sprinklers, the stainless steel option adds …
If the right side of the arc is not properly aligned, the results may be a wet walkway or a dry turf area. The right side arc can easily be realigned. NOTE: Prior to making the right side adjustment, make sure the top turret is reset. Rotate the turret …
The Pro-C controller is modular in design. This means that most controller components can be removed and replaced if needed. For the newer style Pro-C (blue panel and buttons), the part number for the front panel is 821501. The panel fo the older PC-300 …
Rotary sprinklers require a certain amount of pressure and flow to operate properly. If the rotor does not receive the pressure it needs to pop up a leaky head will result. Here are some things to look for when a rotor doesn't pop up properly: Problem: …
Production of the G-Type rotor was discontinued 14 years ago, though many are still in use today. If a G-Type rotor needs to be replaced, the PGP-ADJ or PGP-Ultra is the current equivalent replacement. … Residential Rotors - Equivalent …