STEP ONE STEP TWO 1. From the home screen start by pressing the "Options" button. 2. Continue pressing the "Options" button until "Edit FC Settings" displays. FC stand for "Field Controller" as IDS system's are often referred as in the Golf industry. …
Manual operation allows you to run a manual cycle from 0:01 (one minute) to a maximum of 6:00 (six hours). With the app open, select the MANUAL HAND icon. Select a RUN TIME . Click START . Click STOP to stop the manual operation. … Manual operation …
CONTROLLER SETTINGS offers more advanced features that can be accessed using the steps below. Open the Node-BT App and choose a controller Name. Select Connect . Select the More hamburger icon. Select Controller Settings . Location, Controller Name, …
The Erase All feature will erase all of the controller's memory and set everything back to factory presets. Once you perform an Erase All , all programming will be erased, including the Easy Retrieve saved programming. Erase All is usually performed when …
The DASHBOARD screen provides an overview of the programming within the app. Node controller battery strength (%) - This allows user to determine when battery need to be changed. Controller is set for AUTO or OFF - AUTO means controller will run per …
MANUAL OPERATION will allow you to turn on the following without changing any of the automatic settings. Existing program (A, B or C) - This allows you to turn on a program that has set run times and stations automatically programmed. Single station - …
The chart below indicates the maximum wire runs that can be used when installing Hunter AC solenoid valves with controllers. The example in the chart below demonstrates the most commonly used wire size for station control and ground wire ( e.g.,12 AWG = …
Here is a list of the error codes and ways to troubleshoot them: X2 - Controller code CODE description SOLUTION FAIL Wi-Fi setup failed Check the spelling of the network name (SSID) and/or password and reconnect to Wi-Fi donE The previous operation is …
The CLIK DELAY option is designed to set number of days for watering to remain off, after sensor has been activated and restored. … X2 - …
A Hunter CLIK sensor or closed circuit type weather sensors can be connected to the X2. The purpose of this sensor is to stop automatic watering when weather conditions dictate. … X2 - Connecting a CLIK …
The X2 Controller is compatible with Hunter Remote Controls (not included). The SmartPort® wiring harness (included with all Hunter Remotes) allows for fast and easy use of the Hunter controls. The Hunter remotes make it possible for you to operate the …
NOTE: Complete this section only if you have a master valve installed in your irrigation system. A master valve is a “normally closed” valve installed at the supply point of the main line that opens only when the controller initiates a watering …
If you want to run separate stations (or zones) on different days, you would use 2 different programs. Hunter controllers have multiple programs (A, B, and C) and the ability for each program to have multiple start times. To set up each program, you …
Using the PRB, the regulator in the body will take incoming pressures of 55-100 PSI and reduce them down to 45 PSI. This provides the optimum nozzle pressure to deliver the correct size droplets to the landscape for maximum water efficiency. Please …
The easiest of the rotor pressure gauges to use, the Rotor Pitot Gauge (P/N 280100), has a tube placed directly in front of the primary nozzle stream for an accurate working pressure (dynamic) reading. This gauge will work on all Hunter rotor sprinklers …
Native plant restoration projects and subsurface drip irrigation systems often require temporary overhead watering to support delicate plants. To simplify temporary irrigation, two preassembled stake kits are available for use with high-efficiency MP …
Here are some tips for valve repair. … Valves - Servicing Jar-Top Valves …
All Hunter Industries Anti-Siphon Valves should be installed above ground and at least 6 to 12 inches above the highest sprinkler to prevent back pressure or drainage. Installations at any height lower than this may result in unsafe backflow condition. …
When using the side strip nozzles, there are several different configurations that can be done with any given design. For this reason, we do not publish a PRECIPITATION RATE for these models. We would recommend using the TOTAL AREA METHOD to calculate …
Hunter's MP Rotator is the innovative streaming nozzle that has quickly become the irrigation industries favorite. Multi-trajectory water streams qualify the MP Rotator as a streaming nozzle. Here are a few of the MP's features: Multi-trajectory rotating …
Turn off the controller power using the power switch on the transformer. … Remove the dust cover, or existing module, from the bottom rear of the controller facepack. Push up on the spring-loaded button and pull downward to remove. Slide in the new module …
Turn off the controller power. Tilt and remove the facepack to access the bottom of the facepack. Remove the dust cover or prior module from the controller facepack. Press the spring-loaded button and pull downward to remove. Insert the new A2C-WIFI …
Metal controllers will include a hole plug assembly in a pre-drilled factory hole on top of the controller. Remove the nut on the inside of the controller to remove the plug. Route the cable through the pre-drilled hole and the antenna nut. Then tighten …
Inner Door – Opens to main wiring compartment AC Wiring compartment – For connection of 120/230V AC power with 1 x 0.75" (19 mm) conduit opening Fuse – 2 Amp (fast) 250V, 6 x 20 mm Conduit Openings, Low Voltage – 2" x 2½" (64 mm), 2" x ¾" (19 mm) Wire …