There are two ways to bleed a zone valve for manual operation: … One way is to simply turn the solenoid (the black cylinder with 2 wires) counter-clockwise a 1/4 to 1/2 turn. To shut off the valve, twist the solenoid clockwise until it is snug on the …
There are two reasons why a sprinkler will leak water when the system is supposed to be off. The most common reason is called “Low Head Drainage”. "Low Head Drainage" occurs when the lowest head on a zone allows water to drain from the lateral piping, out …
The most common reason for a valve to remain on, or weep, is debris. New installations without proper flushing, recent mainline repair, or well water can cause debris to flow into the valve and get caught between the diaphragm and the seat. … It's …
… Adjustable heads are preset to approximately 180 degrees. The PGP-ADJ is adjustable from 40-360 degrees. The PGP Ultra is adjustable from 50-360 degrees. Sprinklers may be adjusted with water on or off. It is recommended that initial adjustments be made …
Install the MP Rotator with the Left Edge Indicator (flat side of nozzle) pointing to the left side of the desired watering pattern. The Hunter Pro-Spray two piece ratcheting riser will allow you to align the riser by twisting in either direction after MP …
It is important to understand that Solar Sync provides a global seasonal adjustment to the controller. This means that all station run times will be modified by the seasonal adjustment percentage shown. When programming the controller, the run times …
Use the CONTROLLER OFF feature to stop manual/automatic watering commands, set programmable days off (1-180 days), and set the controller off. Sign in to your C ENTRALUS ACCOUNT . Select a controller name from your CONTROLLER LIST . Click on the …