Residential & Commercial Irrigation
Residential & Commercial Irrigation
CONTROLLER SETTINGS offers more advanced features that can be accessed using the steps below. Open the Node-BT App and choose a controller Name. Select Connect . Select the More hamburger icon. Select Controller Settings . Location, Controller Name, …
The easiest way to make adjustments on your Hunter rotor is to use a Hunter adjustment wrench . This tool can be purchased from your local distributor. There are two adjustments that can be made on your rotor, the arc and the radius . The arc adjustment …
Under the Water Days or Days to Water dial position on your controller you have three options. You can have the program run on specific days, an odd/even schedule, or an interval schedule. To move out of the Interval mode and back into one of your other …
The DASHBOARD screen provides an overview of the programming within the app. Node controller battery strength (%) - This allows user to determine when battery need to be changed. Controller is set for AUTO or OFF - AUTO means controller will run per …
MANUAL OPERATION will allow you to turn on the following without changing any of the automatic settings. Existing program (A, B or C) - This allows you to turn on a program that has set run times and stations automatically programmed. Single station - …
All Hunter controllers will also allow you to program non-water days when utilizing Odd or Even mode. Example: If you mow the lawn on Saturday morning, you may not want the irrigation to come on that day. You can select even watering and Saturday as a …
Hunter's ET System has a wind option that utilizes an anemometer to read local wind conditions. In some cases site conditions may require the anemometer to be located away from the ET Sensor. If this is the case, using 18AWG wire the anemometer can be …
One of your irrigation zones may continue to run or might be stuck on even with your controller unplugged. The valve running without a signal from the controller is an indication that there is debris inside the valve. Here are some tips for valve repair. …
Accu Sync® is a pressure regulation device designed by Hunter to fit all Hunter valves. Accu Sync installs quickly and easily beneath the solenoid on top of your Hunter valve. Swivel assembly allows the regulator to be easily positioned to fit within the …
Manual operation allows you to run a manual cycle from 0:01 (one minute) to a maximum of 6:00 (six hours). With the app open, select the MANUAL HAND icon. Select a RUN TIME . Click START . Click STOP to stop the manual operation. … Manual operation …
Lock and Key sets for Hunter controllers can be purchased at a Hunter Authorized Distributor in your area. PN387300 (spare part) Standard key set PN387301 (spare part) Non-Standard key set PN387302 (spare part) Non-Standard key set Find a Hunter …
The adjustable stator is preset at the factory to match the nozzle installed in the rotor. The purpose of the stator is to maintain a consistent and desirable speed of rotation. Rotors that turn too fast cannot reach their published radius distance. …
STEP ONE STEP TWO 1. From the home screen start by pressing the "Options" button. 2. Continue pressing the "Options" button until "Edit FC Settings" displays. FC stand for "Field Controller" as IDS system's are often referred as in the Golf industry. …
The performance cards will assist you with performance data, rotor installation, nozzle installation, nozzle part numbers, and basic adjustment instructions. Choose from the documents listed below for your specific residential model. … Residential Rotors …
When using the side strip nozzles, there are several different configurations that can be done with any given design. For this reason, we do not publish a PRECIPITATION RATE for these models. We would recommend using the TOTAL AREA METHOD to calculate …
The Hunter Adjustable Arc nozzles come from the factory with a preset arc of 25 degrees. Prior to setting the left side arc, set the right side arc by ratcheting the riser assembly and aligning the right side of the spray pattern. There is no indicator …
Here are some tips for valve repair. … Valves - Servicing Jar-Top Valves …
All Hunter Industries Anti-Siphon Valves should be installed above ground and at least 6 to 12 inches above the highest sprinkler to prevent back pressure or drainage. Installations at any height lower than this may result in unsafe backflow condition. …
Over time general usage can cause riser seals to wear out, similar to the wiper blades on a car, they require replacement. The signs of this are usually heads that have riser stems stuck up after the operation, or excessive leaking around the riser seal …
Hunter manufactures an MP Gauge , this gauge can be used on all Hunter spray heads. Simply screw the Hunter nozzle of your choice onto the MP Adapters top thread, then apply the MP Adapter's bottom thread to the spray head's riser stem. MP Gauge includes: …
When using Centralus Software, you have the ability to change your STATION , BLOCK , and/or DELAY RUN TIMES . There is a maximum run time of 12:00 hrs for all model A2C controllers. The minimum run time is 15 seconds for the decoder model and 1 …
Hunter's MP Rotator is the innovative streaming nozzle that has quickly become the irrigation industries favorite. Multi-trajectory water streams qualify the MP Rotator as a streaming nozzle. Here are a few of the MP's features: Multi-trajectory rotating …
Metal controllers will include a hole plug assembly in a pre-drilled factory hole on top of the controller. Remove the nut on the inside of the controller to remove the plug. Route the cable through the pre-drilled hole and the antenna nut. Then tighten …
After setting up an ACC2 or ICC2 controller in your Centralus account, you may choose to release the controller (serial number) to another user. This will require the controller's deletion. When the NEW user adds the controller into the Centralus …