ICC: Advanced Features

When you select the ICC model under Controller Model, another option becomes available on the Setup menu: Advanced Features. This allows you to set the following special features for an ICC controller:

Programmable Delay Between Stations: You can set a programmable delay between stations in 5-second increments, up to a maximum of 1 minute 40 seconds. This delay is typically used in commercial applications to allow for the slow closing speed of large valves.

Pump/Master Valve Operation: The ICC supports a programmable master valve or pump. Use an X to designate any station or stations that will use the master valve or pump circuit.

Cycle and Soak Settings: The Cycle and Soak feature allows the user to split each station’s run time into more usable, shorter duration waterings. This feature is particularly applicable for slopes and tight soil (such as clay) because Cycle and Soak will help prevent excessive run off. You should enter the Cycle time as a fraction of the station’s watering time and the Soak time as the minimum soak required before watering the next portion. The total number of cycles is determined by taking the total programmed station run time and dividing it by the Cycle time.

The cycle time can be set between 1 and 60 minutes. The ICC allows you to break up a run time into several cycles, each with a specific cycle time. The soak time is the minimum time the controller will delay between cycles. The soak time can be set to any number from 1 to 60 minutes. A default soak time of 30 minutes is set up automatically.