HBV MODELS
HBV-101E – 1" brass globe valve
HBV-151E – 1 1/2" brass globe valve
HBV-201E – 2" brass globe valve
HBV-301E – 3" brass globe valve

DIMENSIONS
HBV-101E – 4 1/2" H x 4 3/8" L x 5 1/2" W (11 cm H x 11 cm L x 14 cm W)
• HBV-151E – 8" H x 6" L x 8" W (20 cm H x 15 cm L x 20 cm W)
• HBV-201E – 9" H x 7" L x 9" W (23 cm H x 18 cm L x 23 cm W)
• HBV-301E – 10" H x 11 5/8" L x 10" W (25 cm H x 29 cm L x 25 cm W)
• HBV-101EP – 4 1/2" H x 4 3/8" L x 5 1/2" W (11 cm H x 11 cm L x 14 cm W)
• HBV-151EP – 8" H x 6" L x 7 1/2" W (20 cm H x 15 cm L x 19 cm W)
• HBV-201EP – 9" H x 7" L x 7 3/4" W (23 cm H x 18 cm L x 20 cm W)
• HBV-301EP – 10" H x 11 5/8" L x 11" W (25 cm H x 29 cm L x 28 cm W)
• Female inlet/outlet: NPT or BSP

OPERATING SPECIFICATIONS
• Flow: 5 to 360 GPM (1.14 to 81.8 m3/hr; 18.9 to 1362 I/min)
• Pressure: 20 to 200 PSI (1.4 to 14.0 bars; 138 to 1379 kPa)
Note: Inlet pressure must exceed outlet pressure by a minimum of 15 PSI
(1.0 bars; 103 kPa) on pressure regulated models
• Electrical: 24VAC, 50/60 cycle solenoid power requirement –
335mA (.335A; 8VA) inrush current; 200mA (.200A; 4.9VA) holding current

OPTIONS AVAILABLE
• Pressure regulation
• BSP threads
• 12-volt DC latching solenoid, field installed (part # S16305)


SPECIFICATION GUIDE
EXAMPLE: HBV - 201E - P
MODEL
HBV
FEATURES
101E = 1" Globe Valve
151E = 1 1/2" Globe Valve
201E = 2" Globe Valve
301E = 3" Globe Valve
OPTIONS
P = Pressure Regulation
B = BSP Threads
DC = DC Latching Solenoid (Field Installed)