| SRC Plus MODELS SRC-600i – 6-station, Indoor Model with 120 VAC Plug-in Transformer SRC-900i – 9-station, Indoor Model with 120 VAC Plug-in Transformer SRC-601i – 6-station, Indoor Model without Plug-in Transformer SRC-901i – 9-station, Indoor Model without Plug-in Transformer DIMENSIONS • SRC Plus: 8 1/4" H x 8 1/2" W x 2 1/4" D (21 cm H x 22 cm W x 6 cm D) SPECIFICATIONS & FEATURES • Station run time: 0-99 minutes in 1-minute increments • Start times: 4 per day, per program, for up to 12 daily starts • Day schedule: 7-day calendar or true odd-even programming with 365-day calendar clock • AM/PM or 24 hour clock option • Start time stacking • One button manual start and advance • Transformer input: 120VAC, 60 Hz (transformer not included with export units) • Transformer output: 24VAC, 0.75A • Station output: 24VAC, 0.35A per station • Maximum total output: 24VAC, 0.7A, includes master valve circuit • Battery: Not required for program backup. 9 volt alkaline battery may be used to program controller in absence of AC power. • Non-volatile memory for program data (no battery required to maintain program) • Master valve output: 24VAC, 0.35A • Surge protection: primary MOV-type • Rain sensor override compatible with most major brands • Test program feature allows for quick system checks. • Preset test cycle on program “C” • UL listed • Central control compatible with Hunter IMMS™ system • Hunter Quick Check™ helps troubleshoot field wiring problems • Electronic Short Circuit Protection; automatically detects and skips shorted stations, no fuses to replace
|
|||||||||||